TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 36 of 1012

TM 9-2350-261-20-2 REPLACE RADIATOR OUTLET ELBOW TO COOLANT PUMP ELBOW HOSE AND TUBE — Continued 0199 00 INSTALLATION 1. Install tube (4) through power plant front access door opening. 2. Secure hose (2) to coolant pump elbow (3) and tube (4) with two clamps (1). 3. Secure hose (6) to radiator outlet elbow (7) and tube (4) with two clamps (5). FOLLOW-THROUGH STEPS 1. Install air cleaner element and housing (WP 0185 00). 2. Fill cooling system (WP 0194 00). 3. Start engine (see your -10). Check for leaks. 4. Stop/shutdown engine (see your -10). 5. Install driver’s power plant access panel (WP 0430 00). 6. Close power plant front access door and raise trim vane (see your -10). END OF TASK 0199 00-2