TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 304 of 1012

TM 9-2350-261-20-2 REPLACE DISTRIBUTION BOX ASSEMBLY FOR 200 AMP GENERATOR SYSTEM (M901A1 ONLY) — Continued 0271 00 2. Install new grommet (5) and circuit 400 lead (6) in distribution box (3). 3. Install new grommet (7) and circuit 450B lead (8) in distribution box (3). Connect circuit 450B lead to circuit breaker (9). NOTE If bilge pump circuit breakers were removed, see WP 0327 00 for installation. If the bilge pump circuit breakers were not removed, go to Step 7. 4. Connect circuit 450C lead (10) to circuit breaker (11). 5. Connect circuit 450A lead (12) to circuit breaker (13). 6. Install 450C lead (10) on bus bar (14). Secure with new lockwasher (15) and screw (16). 7. Install new grommet (17) and circuit 450 lead (18) in distribution box (3). Connect circuit 450 lead to circuit breaker (19). 8. Install new grommet (20) and circuit 2 lead (21) in distribution box (3). 9. Install new grommet (22) and circuit 2A lead (23) in distribution box (3). 0271 00-4