TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 299 of 1012
TM 9-2350-261-20-2 REPLACE DISTRIBUTION BOX ASSEMBLY FOR 200 AMP GENERATOR SYSTEM (M113A2 AND M1064 ONLY) — Continued 0270 00 11. Install new grommet (1) and circuit 10, 14, 15, and 27E lead (2) in distribution box (3). Install circuit 10, 14, 15, and 27E lead and circuit 450A lead (4) on bus bar (5). Secure with new lockwasher (6) and screw (7). 12. For M1064 carrier, install new grommet (8) and circuit 6 lead (9) in distribution box (3). Install circuit 6 lead on bus bar (5). Secure with new lockwasher (10) and screw (11). 13. For M113A2 carrier, install two new grommets (8) and (12), circuit 6 lead (9), and circuit 6L lead (13) in distribution box (3). Install circuit 6 lead and circuit 6L lead on bus bar (5). Secure with new lockwasher (10) and screw (11). 0270 00-5