TM 9-2350-261-20-2 REPLACE DISTRIBUTION BOX ASSEMBLY FOR 100 AMP GENERATOR SYSTEM (M577A2 ONLY) — Continued 0267 00 5. Remove screw (1), lockwasher (2), and circuit 3 lead (3) from circuit breaker (4). Remove circuit 3 lead and grommet (5) from distribution box (6). Discard grommet and lockwasher. 6. Disconnect circuit 450 lead (7) from circuit breaker (8). Remove circuit 450 lead and grommet (9) from distribution box (6). Discard grommet. 7. Disconnect circuit 450B lead (10) from circuit breaker (11). Remove circuit 450B lead and grommet (12) from distribution box (6). Discard grommet. NOTE If bilge pump circuit breakers must be removed, see WP 0327 00 for removal. If bilge pump circuit breakers are not to be removed, go to Step 11. 8. Remove screw (13), lockwasher (14), and circuit 450C lead (15) from bus bar (16). Discard lockwasher. 9. Disconnect circuit 450C lead (15) from circuit breaker (17). 10. Disconnect circuit 450A lead (18) from circuit breaker (19). 11. Remove circuit 400 lead (20) and grommet (21) from distribution box (6). Discard grommet. 12. Remove circuit 2 lead (22) and grommet (23) from distribution box (6). Discard grommet. 0267 00-2