TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 250 of 1012
TM 9-2350-261-20-2 REPLACE HORN AND GROUND LEAD — Continued 0255 00 INSTALLATION 1. Install ground lead (1) on bracket (6). Secure with screw (10), washer (9), new lockwasher (8), and new locknut (7). 2. Install horn (3) on bracket (6). Secure with two new lockwashers (5) and screws (4). 3. Connect circuit 25 lead (2) and ground lead (1) to horn (3). FOLLOW-THROUGH STEPS 1. Turn MASTER SWITCH to ON (see your -10). Press horn button to check that horn works. 2. Turn MASTER SWITCH to OFF (see your -10). END OF TASK 0255 00-2