TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 210 of 1012

TM 9-2350-261-20-2 REPLACE PANEL AND INDICATOR LIGHTS — Continued 0240 00 NOTE Do not disconnect more than one light at a time. Mark each lead to make sure you reconnect to correct contacts. See wiring diagrams at the end of this manual. 2. If required, remove light assembly (4). a. Disconnect circuit lead (5) from light assembly (4). b. Remove two screws (6), lockwashers (7), and light assembly (4) from instrument panel. Discard lockwashers. INSTALLATION NOTE Make sure circuit leads are connected to correct lights. See wiring diagrams at the end of this manual. 1. If removed, install light assembly (1). a. Place light assembly (1) on rear of instrument panel. Secure with two new lockwashers (2) and screws (3). b. Connect circuit lead (4) to light assembly (1). 2. Install light bulb (5). a. Install light bulb (5) in light assembly (1). Push and turn light bulb clockwise to secure. b. Install new packing (6), if damaged, and lens (7) in light assembly (1). Turn lens clockwise to secure. 0240 00-2