TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 208 of 1012

TM 9-2350-261-20-2 REPLACE CIRCUIT BREAKER — Continued 0239 00 INSTALLATION 1. Place circuit breaker (3) on rear of instrument panel. Secure with two screws (5) and new locknuts (4). 2. Connect circuit 27 lead (2) and circuit 10 lead (1) to circuit breaker (3). FOLLOW-THROUGH STEPS 1. Install instrument panel (WP 0238 00). 2. Connect battery ground lead (WP 0294 00). 3. Turn MASTER SWITCH to ON, light should come on for proper installation of circuit breaker (see your -10). 4. Turn MASTER SWITCH to OFF (see your -10). END OF TASK 0239 00-2