TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 200 of 1012
TM 9-2350-261-20-2 REPLACE STARTER GROUND LEADS — Continued 0237 00 CLEANING 1. Remove paint, dirt, and corrosion from electrical contact areas on hull grounds. 2. Check leads. Replace leads that are worn or have cracked insulation. 3. Check lead connectors. Replace cracked or damaged connectors (WP 0312 00). INSTALLATION 1. Place long ground lead (1) on hull mount. Secure with screw (2), two washers (3), and new locknut (4). 2. Place short ground lead (5) on engine block. Secure with washer (6) and screw (7). 3. Place lead (1) and lead (5) and washer (8) on starter (9). Secure with nut (10). FOLLOW-THROUGH STEPS 1. Close power plant front access door (see your -10). 2. Raise trim vane (see your -10). 3. Connect battery ground lead (WP 0294 00). 4. Start engine to check that starter ground leads are operable. Stop/shutdown engine (see your -10). END OF TASK 0237 00-2