TM 9-2350-261-20-2 REPLACE GENERATOR-REGULATOR CIRCUIT BREAKER (100 AMP GENERATOR ONLY) — Continued 0231 00 INSTALLATION NOTE When installing a new generator-regulator circuit breaker, discard two of the four lockwashers supplied with circuit breaker. 1. Place circuit breaker (1) in distribution box (2). Secure with two screws (3) and new locknuts (4). 2. Place circuit 3 lead (5) and terminal strip (6) on circuit breaker (1). Secure with two new lockwashers (7) and two screws (8). 3. Align terminal strip (6) with hole in distribution box (2). Secure with screw (9), two washers (10), and new locknut (11). 4. Place distribution box (2) on hull mounts (12). Secure with five new lockwashers (13) and screws (14). 5. Place master switch panel (15) on distribution box (2). Secure with eight screws (16), washers (17), and new locknuts (18). FOLLOW-THROUGH STEPS 1. Connect battery ground lead (WP 0294 00). 2. Start engine and check the generator-regulator circuit breaker. The BATT-GEN gauge should be in the green (see your -10). 3. Stop/shutdown engine (see your -10). END OF TASK 0231 00-3/4 blank