TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 176 of 1012
TM 9-2350-261-20-2 REPLACE GENERATOR-REGULATOR CIRCUIT BREAKER (100 AMP GENERATOR ONLY) — Continued 0231 00 2. Remove five screws (6), lockwashers (7), and distribution box (5) from hull mounts (8). Discard lockwashers. 3. Remove locknut (9), two washers (10), and screw (11) from terminal strip (12) and distribution box (5). Discard locknut. NOTE Some carriers have four lockwashers on circuit breaker. 4. Remove two screws (13), four/two lockwashers (14), terminal strip (12), and circuit 3 lead (15) from circuit breaker (16). Discard lockwashers. 5. Remove two locknuts (17), screws (18), and circuit breaker (16) from distribution box (5). Discard locknuts. REPAIR OR REPLACEMENT 1. Check terminal strip. Replace circuit breaker that has cracked terminal strip. 0231 00-2