TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 172 of 1012

TM 9-2350-261-20-2 REPLACE REGULATOR ASSEMBLY (100/200 AMP GENERATOR) — Continued 0230 00 NOTE Ground lead is on 200 amp system only. 2. Remove four screws (4), eight lockwashers (5), ground strap (6), and mount plate (7) with attached regulator (3) from hull weldnuts. Discard lockwashers. 3. Remove four screws (8), eight lockwashers (9), and mount plate (7) from regulator (3). Discard lockwashers. 4. Remove nut (10), lockwasher (11), and other end of ground lead (6) from ground stud (12). Discard lockwasher. REPAIR OR REPLACEMENT 1. Check cables. Replace worn or cracked cables and damaged connectors (WP 0312 00, WP 0313 00, or WP 0314 00). 0230 00-2