TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 164 of 1012
TM 9-2350-261-20-2 REPLACE GENERATOR AND ADJUSTMENT LINKAGE (200 AMP GENERATOR ONLY) — Continued 0228 00 INSTALLATION NOTE If installing new generator, begin with Step 1, but remove nut and washer from generator shaft before installing pulley. Nut and washer are not used. If not installing new generator go to Step 4. 1. Install generator mounting bracket (1) on generator (2). Secure with two screws (3), washers (4), and new locknuts (5). Do not tighten. 2. Install key (6) in generator shaft (7). NOTE Position pulley as close to the generator body as possible. Tighten three screws (10) alternately and progressively until they are pulled up tight. 3. Install bushing (8) and pulley (9) on generator shaft (7) with three screws (10). 4. Place generator (2) and mounting bracket (1) on right side sponson in engine compartment. 5. Support generator (2) with 2-inch x 4-inch x 3-foot wood block and align slotted holes in generator mounting bracket (1) with holes in fuel filter bracket (11). Secure with four washers (12) and screws (13). Do not tighten screws. 6. Coat threads of three screws (14) with antiseize compound. 7. Install bracket (15) on transfer gearcase. Secure with two new key washers (16), washer (17), new lockwasher (18), and three screws (14). TIGHTEN SCREWS TO 144-192 LB-IN (16-22 N·M) TORQUE. Use torque wrench and socket wrench set. Bend tabs on key washers. 8. Place jam nut (19) on rod end (20). Install rod ends (20) and (21) in turnbuckle (22). Do not tighten jam nut. 9. Install turnbuckle rod end (21) on generator (2). Secure with spacer (23), screw (24), and new locknut (25). 10. Secure rod end (20) to bracket (15) with screw (26), spacer (27), and new locknut (28). 0228 00-4