TM 9-2350-261-20-2 REPLACE GENERATOR AND ADJUSTMENT LINKAGE (200 AMP GENERATOR ONLY) — Continued 0228 00 NOTE It may be necessary to loosen two screws (20) and swing generator up to remove lower screws (21) from generator mounting bracket. 8. Support generator with wood block and remove two lower screws (21) and washers (22), from generator from mounting bracket (23). 9. Remove two upper screws (21), washers (22), and generator mounting bracket (23) from fuel filter bracket (24). 10. Remove generator (13) and attached mounting bracket (23) from power plant compartment. Have helper assist. NOTE If replacing generator, do Steps 11 - 15. 11. Remove three screws (25) that secure pulley (26) and bushing (27) to generator shaft (28). 12. Install three screws (25) in threaded holes in pulley (26). Tighten screws until bushing (27) separates from pulley. 13. Remove pulley (26) and bushing (27) from generator shaft (28). 14. Remove key (29) from generator shaft (28). 15. Remove two locknuts (30), washers (31), and screws (20) from generator (13) and mounting bracket (23). Remove bracket from generator. Discard locknuts. 0228 00-3