TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 162 of 1012

TM 9-2350-261-20-2 REPLACE GENERATOR AND ADJUSTMENT LINKAGE (200 AMP GENERATOR ONLY) — Continued 0228 00 2. Disconnect cable (7) from generator (8). Remove nut (9), lockwasher (10), and generator ground lead (3) from generator. Discard lockwasher. 3. Remove two cotter pins (1), pin (2), and fan drive tensioner (3) from bracket (4) on transfer gearcase. Discard cotter pins. 4. Remove locknut (5), screw (6), rod end (7), and spacer (8) from bracket (4). Discard locknut. 5. Remove locknut (9), screw (10), rod end (11), and spacer (12) from generator (13). Discard locknut. 6. Remove two rod ends (7) and (11) from turnbuckle (14). Remove jam nut (15) from rod end (7). 7. Remove three screws (16), two key washers (17), lockwasher (18), washer (19), and bracket (4) from transfer gearcase. Discard key washers and lockwasher. 0228 00-2