TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 160 of 1012
TM 9-2350-261-20-2 REPLACE GENERATOR AND ADJUSTMENT LINKAGE (100 AMP GENERATOR ONLY) — Continued 0227 00 NOTE Use straight edge across face of both pulleys to assist in proper alignment. 8. To obtain correct alignment, adjust the position of the generator mounting bracket (11) before you tighten the screws in the slotted holes. Align pulley (12) on generator (13) with drive pulley (14) on transfer gearcase to within 1/8 inch (3.2 mm), then tighten screws (11). 9. Place spacer (15) and rod end (7) on bracket (2). Secure with screw (16) and new locknut (17). 10. Place spacer (18) and rod end (8) on generator (13). Secure with screw (19) and new locknut (20). 11. Connect cable (21) to generator (13). FOLLOW-THROUGH STEPS 1. Connect battery ground lead (WP 0294 00). 2. Install generator drive belts (WP 0226 00). 3. Check generator output for proper operation. 4. Stop/shutdown engine (see your -10). 5. Install power plant rear access panels and support (WP 0431 00). END OF TASK 0227 00-6