TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 157 of 1012
TM 9-2350-261-20-2 REPLACE GENERATOR AND ADJUSTMENT LINKAGE (100 AMP GENERATOR ONLY) — Continued 0227 00 NOTE If replacing generator, do Steps 8 - 10. 8. Remove three screws (10) and washers (11) securing pulley (12) and bushing (13) to generator shaft (14). 9. Use three screws (10) to separate pulley (12) and bushing (13). (Install three screws in three threaded holes of pulley. Tighten screws until you are able to separate pulley from bushing.) 10. Remove pulley (12) and bushing (13) from generator shaft (14). Remove key (15) from generator shaft. 0227 00-3