TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 149 of 1012
TM 9-2350-261-20-2 REPLACE MASTER SWITCH TO DISTRIBUTION BOX WIRE ASSEMBLY (CIRCUIT 49 LEAD) (ALL EXCEPT M577A2 AND M1068) — Continued 0225 00 4. Remove screw (15), washer (16), and circuit 49 lead (9) from distribution box bus bar (17). 5. Remove circuit 49 lead (1) with two grommets (2) from master switch panel (3) and distribution box (4). Discard grommets. REPAIR 1. Check circuit 49 lead for continuity. Use multimeter. Replace bad lead. 0225 00-3