TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 148 of 1012

TM 9-2350-261-20-2 REPLACE MASTER SWITCH TO DISTRIBUTION BOX WIRE ASSEMBLY (CIRCUIT 49 LEAD) (ALL EXCEPT M577A2 AND M1068) — Continued 0225 00 2. Early slave receptacle only: remove locknut (6), two washers (7), screw (8), and circuit 49 lead (9) from circuit 50 lead terminal (10). Discard locknut. 3. Late slave receptacle only: remove locknut (11), circuit 50 lead (12), and circuit 49 lead (13) from master switch terminal (14). Discard locknut. 0225 00-2