TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 146 of 1012
TM 9-2350-261-20-2 REPLACE MASTER SWITCH PANEL ASSEMBLY (EARLY SLAVE RECEPTACLE) (M577A2 AND M1068 ONLY) — Continued 0224 00 19. Install master switch panel (31) on distribution box (32). Secure with eight screws (33), washers (34), and new locknuts (35). FOLLOW-THROUGH STEPS 1. Connect battery ground lead (WP 0294 00). 2. Start engine (see your -10). Check that master switch panel assembly is operable. 3. Stop/shutdown engine (see your -10). END OF TASK 0224 00-8