TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 145 of 1012

TM 9-2350-261-20-2 REPLACE MASTER SWITCH PANEL ASSEMBLY (EARLY SLAVE RECEPTACLE) (M577A2 AND M1068 ONLY) — Continued 0224 00 16. Install circuit 49 lead (21) on bottom terminal of master switch (12). Secure with washer (22) and nut (23). 17. Connect wiring harness (24) leads (25), (26), and (27) to three circuit breakers (28), (29), and (30). 18. Replace gasket between master switch panel and distribution box, if damaged (WP 0266 00). 0224 00-7