TM 9-2350-261-20-2 REPLACE MASTER SWITCH PANEL ASSEMBLY (EARLY SLAVE RECEPTACLE) (M577A2 AND M1068 ONLY) 0224 00 THIS WORK PACKAGE COVERS: Removal (page 0224 00-1). Installation (page 0224 00-5). INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0780 00, Item 29) M a t e r i a l s / P a r t s Grommet (11) Lockwasher Locknut (8) P e r s o n n e l R e q u i r e d Unit Mechanic E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) Battery ground lead disconnected (WP 0294 00) REMOVAL NOTE Step 6 is for 200 amp generator system only. All other steps are common. 1. Remove eight locknuts (1), washers (2), and screws (3). Separate master switch panel assembly (4) from distribution box (5). Discard locknuts. 2. Disconnect wiring harness (6) leads (7), (8), and (9) from three circuit breakers (10), (11), and (12). 3. Remove nut (16), washer (17), and circuit 49 lead (13) from bottom terminal on master switch (14). 0224 00-1