TM 9-2350-261-20-2 REPLACE MASTER SWITCH PANEL ASSEMBLY (EARLY SLAVE RECEPTACLE) (ALL EXCEPT M577A2) — Continued 0223 00 3. Remove screw (8), locknut (9), washer (10), and ground lead (11) from instrument panel strut (12). Discard locknut. 4. Remove circuit 49 lead (13), circuit 6 lead (14), and two grommets (15) from master switch panel assembly (6). Discard grommets. 5. Remove nut (1), screw (2), two lockwashers (3), and circuit 49 lead (4) from auxiliary power receptacle lead (5). Discard lockwashers. 6. Remove locknut (6), screw (7), circuit 6 lead (8), circuit 2 lead (9), and circuit 400 lead (10) from bus bar (11). Discard locknut. NOTE For all carriers with 200 amp generator, do Step 7. 7. Remove nut (12), lockwasher (13), and circuit 2A lead (14) from master switch terminal (15). Discard lockwasher. 8. Remove master switch panel (16) from carrier. 0223 00-2