TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 135 of 1012
TM 9-2350-261-20-2 REPLACE MASTER SWITCH PANEL ASSEMBLY (EARLY SLAVE RECEPTACLE) (ALL EXCEPT M577A2) 0223 00 THIS WORK PACKAGE COVERS: Removal (page 0223 00-1). Installation (page 0223 00-3). INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0780 00, Item 29) M a t e r i a l s / P a r t s Grommet (2) Lockwasher (3) Locknut (2) Locknut (8) P e r s o n n e l R e q u i r e d Unit Mechanic E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) Battery ground lead disconnected (WP 0294 00) Infrared power supply cable disconnected from master switch panel (WP 0291 00) REMOVAL 1. Disconnect circuit 37 lead (1) from connector (2). 2. Remove eight locknuts (3), washers (4), and screws (5). Separate master switch panel assembly (6) from distribution box (7). Discard locknuts. 0223 00-1