TM 9-2350-261-20-2 REPLACE MASTER SWITCH ASSEMBLY — Continued 0221 00 5. Install circuit 49 lead (6) and circuit 50 lead (10) on terminal (7). Secure with new lockwasher (8) and nut (9). 6. Install master switch panel (11) on distribution box (12). Secure with eight screws (13), washers (14), and new locknuts (15). 0221 00-6