TM 9-2350-261-20-2 REPLACE MASTER SWITCH ASSEMBLY — Continued 0221 00 2. Place knob (13) on master switch (14). Secure with washer (12) and screw (11). NOTE Carriers that have 100 amp generators do not have circuit 2A. 3. Install conductor bus (1) with attached leads and circuit 2A lead (2) on terminal (3). Secure with new lockwasher (4) and nut (5). NOTE On M577A2 and M1068 carriers, do Step 4 then go to Step 6. On all other carriers, after Step 3 go to Step 5. 4. Install circuit 49 lead (6) on master switch terminal (7). Secure with new lockwasher (8) and nut (9). 0221 00-5