TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 123 of 1012

TM 9-2350-261-20-2 REPLACE MASTER SWITCH ASSEMBLY — Continued 0221 00 4. Remove nut (1), lockwasher (2), circuit 50 lead (3), and circuit 49 lead (4) from master switch terminal (5). Discard lockwasher. NOTE Carriers that have 100 amp generators do not have circuit 2A. 5. Remove nut (6), lockwasher (7), circuit 2A lead (8), and conductor bus (9) with attached leads from master switch terminal (10). Discard lockwasher. 0221 00-3