TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 118 of 1012
TM 9-2350-261-20-2 REPLACE NATO AUXILIARY POWER (SLAVE) RECEPTACLE (M577A2 AND M1068 ONLY) — Continued 0220 00 REMOVAL 1. Remove seven screws (1), lockwashers (2), washers (3), and harness protector (4) from hull. Discard lockwashers. 2. Remove screw (5), washer (6), clamp (7), and circuit 50 lead (8) from hull weldnut. 3. Remove four screws (9), lockwashers (10), and washers (11) from receptacle (12). Discard lockwashers. 4. Pull receptacle (12) and adapter (13) away from hull. 5. Remove screw (14), lockwasher (15), and circuit 6 lead (16) from positive terminal of receptacle (12). Discard lockwasher. 6. Remove screw (17), lockwasher (18), and circuit 50 lead (8) from negative terminal of receptacle (12). Discard lockwasher. 7. Remove four screws (19), lockwashers (20), and washers (21) from adapter (13). Discard lockwashers. 8. Remove receptacle (12), gasket (22), insulator (23), adapter (13), and gasket (24) from hull. Discard gaskets. 9. Remove insulator bushing (25) from hull. 0220 00-2