TM 9-2350-261-20-2 REPLACE AUXILIARY POWER (SLAVE) RECEPTACLE (M577A2 AND M1068 ONLY) — Continued 0219 00 INSTALLATION NOTE Steps 1 - 8 tell you how to install the late model slave receptacles. Steps 9 - 11 tell you how to install the early model slave receptacles. NOTE Perform Step 1 only if receptacle is mounted on an adapter (1). 1. If adapter (1) is used, place new gasket (2) and adapter in hull. Secure with four washers (3), new lockwashers (4), and screws (5). 2. Install new bushing (6) in adapter (1) or in hull. 3. Connect ground lead (7) to negative (−) side of post on receptacle (8). Secure with screw (9) and new lockwasher (10). 4. Place plate insulator (11) and new gasket (12) on adapter (1) or hull. 5. Insert ground lead (7) into bushing (6) far enough to connect circuit 6 lead (13) to positive (+) side of post on receptacle (8). Secure with screw (9) and new lockwasher (10). 6. Secure receptacle (8) with plate insulator (11) and gasket (12) to adapter (1) or hull with four screws (14), new lockwashers (15), and washers (16). 7. Inside carrier, install ground lead (7) to hull. Secure with screw (17) and new lockwasher (18) in clamp (19). 8. Inside carrier, fit ground lead (7) into wiring cradle (20). Secure with clip (21). 0219 00-4