TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 112 of 1012

TM 9-2350-261-20-2 REPLACE AUXILIARY POWER (SLAVE) RECEPTACLE (M577A2 AND M1068 ONLY) — Continued 0219 00 1. Remove seven screws (1), lockwashers (2), washers (3), and guard (4) from hull interior. Discard lockwashers. 2. Remove four screws (5), lockwashers (6), and washers (7) from receptacle (8). Discard lockwashers. 3. Remove screw (9), washer (10), clamp (11), and circuit 50 lead (12) from hull weldnut. 4. Pull receptacle (8) away from hull. Unsolder circuit 6 lead (13) from receptacle. Remove receptacle. Use soldering torch. 5. Remove seven screws (1), lockwashers (2), washers (3), and guard (4) from hull interior. Discard lockwashers. 6. Remove screw (5) and lockwasher (6) from clamp (7) securing ground lead (8) to hull. Discard lockwasher. 7. Remove clip (9) from wiring cradle (10) on hull. Free up ground lead (8) from cradle and clip. 8. Remove four screws (11), lockwashers (12), and washers (13) securing receptacle (14) to adapter (15) or hull. Discard lockwashers. 9. Push down on bushing (16) inserted into adapter (15) or hull. Pull receptacle (14) up far enough to expose screws (17), and leads (8) and (18) attached. 10. Remove screw (17), lockwasher (19), and circuit 6 lead (18) from positive (+) side of post on receptacle (14). Discard lockwasher. 11. Remove receptacle (14) and bushing (16) from hull. Remove screw (17), lockwasher (19), and ground lead (8) from negative () side of post on receptacle (14). Discard lockwasher and bushing. 0219 00-2