TM-9-2350-261-20-2 Unit Maintenance Manual Volume 2 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 107 of 1012
TM 9-2350-261-20-2 REPLACE AUXILIARY POWER (SLAVE) RECEPTACLE (ALL EXCEPT M577A2 AND M1068) — Continued 0218 00 10. Remove four screws (16), washers (17), locknuts (18), and auxiliary power receptacle (11) from master switch panel (6). Discard locknuts. 11. Remove nut (19) and washer (20) on master switch (21). Remove circuit 50 lead (9) and circuit 49 lead (22) from master switch terminal (23). 12. Remove nut (24), washer (25), screw (26), and ground lead (14) from instrument panel strut hull mount. 13. Remove gasket (27), insulator (28), and grommet (29) from master switch panel (6). Remove grommet from ground lead (14). Discard grommet and gasket. 0218 00-3