TM 9-2350-261-20-2 REPLACE PULLEY DRIVE SHAFT, BEARING, AND HOUSING — Continued 0217 00 6. Secure housing (2) to support (8) with three new key washers (9) and screws (10). TIGHTEN SCREWS TO 300-360 LB-IN (34-41 N·M) TORQUE. Use torque wrench. FOLLOW-THROUGH STEPS 1. Install fan pulley (WP 0214 00). 2. Install fan drive belts (WP 0211 00). 3. Install fan pulley access cover (WP 0214 00). 4. Adjust fan drive belt tension (WP 0211 00). 5. Install power plant rear access panel (WP 0431 00, WP 0432 00, or WP 0433 00). 6. Raise and lock ramp (see your -10). 7. Stop/shutdown engine (see your -10). END OF TASK 0217 00-3/4 blank