TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 951 of 1236

TM 9-2350-261-20-1 CLEAN FUEL CAP VENT AND FILTER SCREEN (M981 AND M1064 ONLY) — Continued 0150 00 WARNING Air pressure in excess of 30 psi (207 kPa) can injure personnel. Do not direct pressurized air at yourself or others. Always wear goggles. f. Clean screen cap (8) with dry cleaning solvent. Dry with compressed air. g. Install screen cap (8) in fuel cap (2). Dry with compressed air. 5. While holding one end of spring plate (6), place other end in groove in filler neck (3). Rotate spring plate and install in filler neck. 6. Install hook (4) with attached chain (5) and fuel cap (2) to spring plate (6). 7. Install fuel cap (2), with attached chain (5) in filler neck (3). 8. Close fuel filler combat cover (1). END OF TASK 0150 00-3/4 blank