TM 9-2350-261-20-1 DRAIN EXTERNAL FUEL TANKS (M981 AND M1064 ONLY) — Continued 0142 00 WARNING Fuel flowing over a metal surface causes static electricity. This will cause a spark unless the surface is grounded. NOTE Use wiping rag to wipe up any spilled fuel. 3. Ground container (2) to carrier. 4. Close both fuel tank shutoff valves (see your -10). 5. Remove plug (4) from fuel tank (3). Drain fuel. 6. Install plug (4) in fuel tank (3) after the tank has been drained. 7. Install fuel filler cap (see your -10). Close filler combat cover (1). FOLLOW-THROUGH STEPS 1. Connect battery ground strap (WP 0294 00). 2. After maintenance has been performed, fill fuel tanks (see your -10). END OF TASK 0142 00-2