TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 833 of 1236

TM 9-2350-261-20-1 RAISE/LOWER POWER PLANT GRILL — Continued 0130 00 NOTE Use coolant in cooling system at all times. It will reduce corrosion in engine block and provide low temperature protection. Mix coolant and clean water based on the requirements for your carrier. Use tester. 23. Fill cooling system slowly with 14 gallons (53 liters) of coolant and water until level is within 1/2 inch (13 mm) of filler neck (WP 0194 00). 24. Replace coolant filler cap (see your -10). WARNING Carbon monoxide is poisonous and can kill you. Do not idle engine with power plant access panels off unless there is VERY GOOD AIR FLOW. 25. Connect battery ground lead (WP 0294 00). 26. Start engine (see your -10). Check that power plant grill is installed properly and the cooling system does not leak. WARNING Hot coolant can burn you. Do not remove radiator cap until coolant temperature gauge reads in bottom one-quarter of green zone. Use heat protective mittens to turn radiator cap. Turn cap slowly to release pressure. 27. Check coolant level (see your -10). FOLLOW-THROUGH STEPS 1. Engine stopped/shutdown (see your -10). 2. Install power plant upper rear access panel (WP 0431 00, WP 0432 00, or WP 0433 00). 3. Install driver’s power plant access panel (WP 0430 00). 4. Close power plant front access door (see your -10). 5. Raise trim vane (see your -10). END OF TASK 0130 00-19/20 blank