TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 828 of 1236
TM 9-2350-261-20-1 RAISE/LOWER POWER PLANT GRILL — Continued 0130 00 WARNING Lifting or moving objects in excess of 70 pounds could injure you. Get an assistant or use a lifting device to move heavy objects. 8. On M577A2 and M1068 only, secure 4.2 KW generator enclosure (8) or 5.0 KW APU to hull with six screws (9), eight washers (10), and two new locknuts (11). TIGHTEN FOUR SCREWS THAT SECURE REAR ENCLOSURE TO HULL TO 55–60 LB-FT (75–81 N·M) TORQUE. Use torque wrench. 0130 00-14 7. On M577A2 and M1068 only, position 4.2 KW generator enclosure (8) or 5.0 KW APU on hull. Use davit for 4.2 KW generator enclosure (see your -10) or suitable lifting device (capable of lifting 600 lb (273 kg)) for 5.0 KW APU.