TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 779 of 1236
TM 9-2350-261-20-1 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0120 00 Table 19. Annual Unit Level Preventive Maintenance Checks and Services for M113A2 FOV ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED CREWMEMBER PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 1 Annual 0.4 Carrier a. Lubricate tachometer and speedometer shafts annually with GIA (Table 11, page 0120 00-17). b. Disconnect shafts at both ends (WP 0246 00 and WP 0248 00), remove slotted washers from drive ends of cores, and remove cores from instrument panel end of shafts. c. Clean, inspect, and lubricate cores. Insert cores in shafts. Install slotted washers and connect both ends of shafts. If tachometer adapter has a grease fitting, lubricate sparingly with GIA. 0120 00-151