TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 768 of 1236
TM 9-2350-261-20-1 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0120 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED CREWMEMBER PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 108 Semi-annual Personnel Heater Kit a. Tighten loose mounting screws and clamps. Any fuel, coolant, or exhaust leaks. b. Remove control cover by turning two screws to the left. c. Check flame detector switch and ignition control. See TM 9-2540-205-24&P or TM 9-2540-207-14&P. d. Check heater fuel pump, fuel lines, and connections for leaks. Replace connections that continue to leak. e. Check for signs of exhaust leaks. Tighten clamps. 0120 00-140