TM 9-2350-261-20-1 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0120 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED CREWMEMBER PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: NOTE Additional data on chemical Agent Automatic Alarm Kit for the M113 FOV can be found in: Operator’s and Unit Manual TM 3-6665-225-12 Repair Parts and Special Tools List TM 9-2350-261-24P d. Check mounting screws on junction box. Tighten loose screws in junction box. TIGHTEN LOOSE SCREWS TO 72 LB-IN (8 N·M) TORQUE. Use torque wrench (WP 0780 00, Item 100) and socket set (WP 0780 00, Item 96). e. Check grommet. Replace cracked or worn grommet. f. Check cable and circuit breaker terminal. Tighten loose connections. Replace damaged terminals (WP 0774 00). g. Check cables. Replace frayed or cracked cables (WP 0775 00). 0120 00-128