TM 9-2350-261-20-1 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0120 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED CREWMEMBER PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 57 Semi-annual Air Cleaner WARNING Air pressure in excess of 30 psi (207 kPa) can injure personnel. Do not direct pressurized air at yourself or others. Always wear goggles. NOTE You will have one of two air cleaner configerations. Body and elements are NOT interchangeable, except as sets. a. Clean or replace air cleaner element (WP 0182 00). Latches or element is missing, damaged, or broken. Gasket is torn or separated from element. 0120 00-74