TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 678 of 1236

TM 9-2350-261-20-1 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0120 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED CREWMEMBER PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 32 Semi-annual Mortar Base Stowage Brackets (M1064 Only) a. Ensure that bracket (1) closes and locks properly. Check brackets (1) and (2) for cracks. Tighten or replace base or missing bolts on brackets (1) and (2) (WP 0544 00). 33 Semi-annual Generator Set Enclosure (M577A2) a. TIGHTEN OR REPLACE LOOSE OR MISSING SCREWS ON ENCLOSURE TO 55–60 LB-FT (75–81 N·M). Use torque wrench (WP 0780 00, Item 104). b. Replace damaged enclosure (WP 0472 00). 0120 00-50