TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 612 of 1236
TM 9-2350-261-20-1 STE/ICE-R TEST 14 COMPRESSION UNBALANCE (POWER CABLE) — Continued 0113 00 h. Set TEST SELECT switches to 06. i. Press and release TEST button. j. Wait for VTM to display the Cu-1 prompting message. k. Set TEST SELECT switches to the value of the Cu-1 constant. l. Press and release TEST button. m. Wait for VTM to display the Cu-2 prompting message. n. Set TEST SELECT switches to the value of the Cu-2 constant. o. Press and release TEST button. p. Wait for VTM to display the Cu-3 prompting message. q. Set TEST SELECT switches to the value of the Cu-3 constant. r. Press and release TEST button. s. Wait for VTM to display the Cu-4 prompting message. t. Set TEST SELECT switches to the value of the Cu-4 constant. u. Press and release TEST button. v. Wait for VTM to display the Cu-5 prompting message. w. Set TEST SELECT switches to the value of the Cu-5 constant. x. Press and release TEST button. y. When GO appears, crank engine. Display will change to (----) while engine is turning. NOTE If E013 appears, test data cannot be analyzed because of weak batteries or interrupted cranking during test. Correct problem and repeat Step 2. z. When OFF or E013 appears, stop cranking. Wait for message to appear. 1) If a number is displayed, refer to the vehicle test card for its meaning. 2) If GO appears, go back to Step 2y. 3) A FAIL message usually means compression is too far unbalanced to measure with STE/ICE-R. Occasionally, a FAIL message may be caused by carrier/equipment accessories that are activated during cranking or by imperfections in the starting system. 0113 00-2