TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 602 of 1236
TM 9-2350-261-20-1 HOOK UP/REMOVE STE/ICE-R TEST SET FOR TEST NUMBERS 72 THRU 75 — Continued 0109 00 7. For test numbers 72 (WP 0115 00) or 74 (WP 0117 00), current probe (4) is connected to positive cable (5) between battery (6) and starter (7). Point arrow on current probe along cable to starter. Make sure current probe is closed. 8. For test numbers 73 or 75 (WP 0116 00), clamp current probe (1) around cable (2) connecting series pair of batteries (3). Point arrow on current probe along cable toward negative (-) terminal (4). Make sure current probe is closed. 0109 00-2