TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 597 of 1236
To prevent cable damage, make sure cable is clear of belts and fan blade. 6. Connect cable W4 P2 (6) to pulse tachometer (5). N O I TM 9-2350-261-20-1 T U A HOOK-UP 1. Remove transducer cable W4 and pulse tachometer from transit case. 2. Pull VTM circuit breaker to OFF. 3. Connect cable W4 P1 (1) to jack J2 TK (2) on VTM. 4. Disconnect tachometer cable (3) from tachometer drive adapter (4) on engine (WP 0246 00). 5. Install pulse tachometer (5) on tachometer drive adapter (4). C Engine stopped (see your -10) Carrier blocked (see your -10) STE/ICE-R power hooked up (WP 0106 00) Power plant rear access panel removed (WP 0431 00, WP 0432 00, or WP 0433 00) n o i t i d n o HOOK UP/REMOVE STE/ICE-R FOR ENGINE RPM 0107 00 C t n e m p i u q WP 0246 00 E s e c n THIS WORK PACKAGE COVERS: Hook-up (page 0107 00-1). Removal (page 0107 00-2). e r e f INITIAL SETUP: M e a Unit Mechanic R i d n e t r e i n u a q n e c R e l L e e n v n e o l s r Unit T e o General Mechanic’s Tool Kit (WP 0780 00, Item 29) STE/ICE-R Test Set (WP 0780 00, Item 73) P o s l l s o o a T n d l a S i p c e 01 0 7 00-1