TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 596 of 1236

TM 9-2350-261-20-1 HOOK UP/REMOVE STE/ICE-R FOR POWER — Continued 0106 00 6. Connect black clip of power cable W5 to negative terminal of battery. 7. Push VTM circuit breaker to ON. a. If display reads (8888) and (– – – –), go to Step 8. b. If display is not blank, but does not read (8888) and (– – – –), write up DA Form 2404 on faulty VTM display. Report problem to supervisor. c. If display is blank, go to VTM blank display diagnostic troubleshooting. See TM 9-4910-571-12&P. 8. Perform VTM confidence check, see TM 9-4910-571-12&P. If VTM confidence check does not pass, go to STE/ICE confidence test fault isolation, see TM 9-4910-571-12&P. 9. Select test 60, then press and release TEST button. 10. Enter carrier VID (03) into VTM, then press and release TEST button. 11. Select test 61, then press and release TEST button. If carrier VID (03) does not appear on VTM display, see TM 9-4910-571-12&P. 12. Return to troubleshooting. REMOVAL 1. Pull VTM circuit breaker to OFF. 2. Remove power cable W5 from batteries and VTM. Use electrical connector pliers. 3. Install battery cover (see your -10). 4. Stow VTM and power cable W5 in transit case. 0106 00-2