TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 589 of 1236
TM 9-2350-261-20-1 STE/ICE-R ENGINE WILL NOT CRANK TROUBLESHOOTING 0104 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0780 00, Item 29) P e r s o n n e l R e q u i r e d Unit Mechanic E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) Power plant access door open (see your -10) Trim vane lowered (see your -10) T 1. Engage starter switch and listen to starter. 2. Does starter sound like it is running over speed? TN 1. Go to Starter Circuit Troubleshooting (WP 0101 00). 2. Verify no faults found. Y 1. Remove starter (WP 0236 00). 2. Check for missing or damaged teeth on flywheel. 3. Are all teeth good? YN 1. Notify direct support maintenance. 2Y 1. Check bendix spring, starter, or solenoid. 2. Replace parts as needed. 3. Verify no faults found. 01 0 4 00-1/2 blank