TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 578 of 1236
TM 9-2350-261-20-1 STE/ICE-R STARTER CIRCUIT TROUBLESHOOTING — Continued 0101 00 3Y 1. Check batteries to make sure they are fully charged. See TM 9-6140-200-14. 2. Verify no faults found. BY 1. Check to see if E013 is displayed. 2. Is E013 displayed? BYN 1. Check batteries to make sure they are fully charged. See TM 9-6140-200-14. 2. Verify no faults found. B2Y 1. Crank engine (see your -10). 2. Does any message appear other than GO? B2YN GO TO C2Y (PAGE 0101 00-3) B3Y 1. Check how many times E013 has been displayed. 2. Is this the third time E013 was displayed? B3YN 1. Repeat this part of troubleshooting. B4Y 1. Turn off all electrical equipment. 2. Set test select switches to 90. 3. Press and hold test until CAL appears on display. 4. Is offset value within limits of −225 to +225? B4YN 1. Go to Offset Fault Isolation. See TM 9-4910-571-12&P. 2. Verify no faults found. B5Y 1. Press and release test button. 2. Crank engine for a few seconds with fuel off. 3. Is starter current above 100 amps? B5YN 1. Check batteries. See TM 9-6140-200-14. 2. Verify no faults found. 0101 00-2