TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 575 of 1236

TM 9-2350-261-20-1 STE/ICE-R CHARGING CIRCUIT TROUBLESHOOTING — Continued 0100 00 FIELD CURRENT CY 1. Install current probe around circuit 1 lead of generator to regulator cable. 2. Point arrow on current probe toward generator. 3. Set test select switches to 01. 4. Press and release test button. 5. When PASS appears, set test select switches to 90. 6. Press and release test button. 7. Raise engine speed to 1000 to 1200 RPM and read RPM display. 8. Stop engine (see your -10). 9. Is current below 6 amps? CYN 1. Go to Charging System Malfunctions (WP 0018 00). 2. Verify no faults found. C2Y 1. Check continuity of cables from regulator to generator. 2. If cables are ok, go to Charging System Malfunctions (WP 0018 00). 3. Verify no faults found. 0100 00-3/4 blank