TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 554 of 1236

TM 9-2350-261-20-1 STE/ICE–R PROCED URE S (SIMPLIFIED TEST EQU IPMEN T FOR INTERNAL COMB USTION EN GINES REP ROGR AMMABLE) — Continued 0099 00 e. Power Cable W5. The power cable W5 is used to power the VTM when cable W1 is not being used. Cable W5 is divided into two leads with color coded clips: red for E1 and black for E2. Battery clips E1 and E2 are attached to a vehicle/equipment battery or a 9 to 32 volt 4A regulated power supply. Do not connect the VTM to a battery charger. Damage to the VTM may result. TRANSDUCER KIT (TK) The transducer kit (TK) is a tray inside the transit case that contains transducers, adapters, and fittings. The TK is stored in a molded tray in the top of the transit case. Many of the fittings do not have part number markings on them and are referred to by TK item number and name. Each fitting is identified by TK item number and part number. MANUAL TM 9-4910-571-12&P contains operating instructions, operator and organizational maintenance instructions, and repair parts and special tools information. 0099 00-6