TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 530 of 1236
TM 9-2350-261-20-1 PHONE EXTENSION BOX A14 POST(S) INOPERATIVE (M1068 ONLY) — Continued 0094 00 T 1. Remove cable W129 plug P2 (1) from phone extension box A14 jack J1 (2). 2. Measure resistance between posts (3) and pins of jack J1 (2) as follows: Post 1 (Blk) to pin A Post 7 (Blk) to pin N Post 1 (Red) to pin B Post 7 (Red) to pin P Post 2 (Blk) to pin C Post 8 (Blk) to pin R Post 2 (Red) to pin D Post 8 (Red) to pin S Post 3 (Blk) to pin E Post 9 (Blk) to pin T Post 3 (Red) to pin F Post 9 (Red) to pin U Post 4 (Blk) to pin G Post 10 (Blk) to pin V Post 4 (Red) to pin H Post 10 (Red) to pin W Post 5 (Blk) to pin J Post 11 (Blk) to pin X Post 5 (Red) to pin K Post 11 (Red) to pin Y Post 6 (Blk) to pin L Post 12 (Blk) to pin Z Post 6 (Red) to pin M Post 12 (Red) to pin a 3. Does multimeter read 0 ohms for each measurement? TN 1. Replace phone extension box A14. See TM 11-7010-256-12&P. 2. Verify no faults found. 0094 00-2