TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 525 of 1236
TM 9-2350-261-20-1 NO LAN OUTPUT FROM DATA PANEL A13 (M1068 ONLY) 0093 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s Digital Multimeter (WP 0780 00, Item 43) Electronic Equipment Tool Kit (WP 0780 00, Item 81) P e r s o n n e l R e q u i r e d Signal Support System Specialist 31U10 Helper (H) E q u i p m e n t C o n d i t i o n Engine stopped/shutdown (see your -10) Carrier blocked (see your -10) WARNING HIGH VOLTAGE is used in the operation of this equipment. DEATH ON CONTACT may result if personnel fail to observe safety precautions. NEVER work on equipment unless at least one other person familiar with the operation and hazards of the equipment is nearby. That person should also be familiar with giving first aid. When an operator helps a mechanic, that operator must be warned about dangerous areas. SHUT OFF POWER supply to equipment before beginning work. Make sure all external power is off/disconnected. BE CAREFUL not to contact high-voltage connections when installing or operating this equipment. 0093 00-1